Docsity
Docsity

Prepare for your exams
Prepare for your exams

Study with the several resources on Docsity


Earn points to download
Earn points to download

Earn points by helping other students or get them with a premium plan


Guidelines and tips
Guidelines and tips

BOMA HVAC Study Set with Questions and Verified Solutions, Exams of Engineering

BOMA HVAC Study Set with Questions and Verified Solutions In an A/C system where air comes from both a hot duct and a cold duct that is supplied from a mixing terminal is called ANSWER A dual duct system An A/C system in which the zone control is obtained by mixing hot and cold air at the unit in response to a room thermostat is called a ANSWER Multizone system Heating and cooling load calculations take the _______________ into consideration. ANSWER Sensible heat and latent heat Which of the following does not provide sensible heat gain? ANSWER Heat from cooking or hot baths. (latent heat has to do with moisture) Which of the following is the way that solar radiation disperses in a building? ANSWER Transmitted directly to the interior of the building, absorbs by glass, reflected into the building Outside air may get into the air conditioning spaces by ANSWER Infiltration through the walls, infiltration through the swinging of doors, air induced by replaced exhaust. In commercial

Typology: Exams

2023/2024

Available from 12/21/2024

school-inspector
school-inspector 🇺🇸

2

(1)

4.5K documents

1 / 34

Toggle sidebar

This page cannot be seen from the preview

Don't miss anything!

bg1
pf3
pf4
pf5
pf8
pf9
pfa
pfd
pfe
pff
pf12
pf13
pf14
pf15
pf16
pf17
pf18
pf19
pf1a
pf1b
pf1c
pf1d
pf1e
pf1f
pf20
pf21
pf22

Partial preview of the text

Download BOMA HVAC Study Set with Questions and Verified Solutions and more Exams Engineering in PDF only on Docsity!

In an A/C system where air comes from both a hot duct and a cold duct that is supplied from a mixing terminal is called ANSWER A dual duct system An A/C system in which the zone control is obtained by mixing hot and cold air at the unit in response to a room thermostat is called a ANSWER Multizone system Heating and cooling load calculations take the into consideration. ANSWER Sensible heat and latent heat Which of the following does not provide sensible heat gain? ANSWER Heat from cooking or hot baths. (latent heat has to do with moisture) Which of the following is the way that solar radiation disperses in a building? ANSWER Transmitted directly to the interior of the building, absorbs by glass, reflected into the building Outside air may get into the air conditioning spaces by ANSWER Infiltration through the walls, infiltration through the swinging of doors, air induced by replaced exhaust. In commercial buildings heat generated by lights does not seriously affect the control of the heating system. ANSWER False The humans body's feeling of well being depends upon ANSWER the body's metabolism